MODEL 2501 COMMERCIAL TILT-IN DOUBLE HUNG
TEST DATA: |
|||
|
Structural Performance Class (AAMA/NWWDA 101/I.S. 2-97) Water Penetration Resistance Air Infiltration @ 1.56 PSF (25 mph) Operating Force (4'6" x 7'6" Window) Forced Entry Resistance (All ASTM tests except Glazing Impact)
|
H-C50 7.5 PSF 0.22 cfm/ft² Less than 45 Lbs. allowable No Entry |
||
|
Test results are based on independent laboratory testing of sizes prescribed by the corresponding AAMA test procedures. Actual field conditions, locations or variations in window size may introduce some deviation between these results and actual installed performance. Customization and alternate
details can be provided to fit your specific needs. NORTHERN
BUILDING PRODUCTS, Inc. |
|||