AAMA/NWWDA
101/I.S.2-97 TEST REPORT
Rendered
to:
REPCO
510 Station Avenue
Bensalem, Pennsylvania 19020
Report
No: 01-34654.01
Test Date: 05/04/99
Report Date: 06/07/99
Expiration Date: 05/04/03
Project Summary
Architectural
Testing Inc. (ATI) was contracted to perform
tests on a Series/Model 1290, aluminum double
hung window. The sample tested successfully
met the performance requirements for a H-C55
54 x 90 rating. Test specimen description and
results are reported herein.
Test
Specification
AAMA/NWWDA
101/I.S.2-97, Voluntary Specification for Aluminum,
Vinyl (PVC) and Wood Windows and Glass Doors.
| Test Specimen
Description |
|
| Series/Model
|
1290 |
| Type |
Aluminum Double
Hung Window (Side-Load) |
| Overall Size |
4'6-¼'' wide
by 7'8-¼'' high |
| Interior Sash
Size |
4'4'' wide
by 3'9-1/8'' high |
| Exterior Sash
Size |
4'4'' wide
by 3'9-1/8'' high |
| Screen Size |
4'4'' wide
by 3'9'' high |
| Finish |
All aluminum
was painted brown |
| Glazing Details |
Both sashes
utilized 7/8"" thick insulating glass fabricated
from two sheets of 1/8'' thick clear annealed
glass and a desiccant filled metal spacer
system. The insulating glass was channel
glazed utilizing a flexible wedge gasket.
|
| Weatherstripping |
| Description |
Quantity |
Location |
| 0.170'' high by 0.187''backed
polypile with center fin |
1 Row |
Head, still and stiles |
| 0.310'' high by 0.187''backed
polypile with center fin |
1 Row |
Interior meeting rail |
| 0.350'' diameter custom hollow
vinyl bulb seal |
1 Row |
Bottom
rail |
Frame
Construction : The frame was constructed
of extruded aluminum members that employed a
poured-in-place urethane thermal break. The
corners were coped, butted, sealed and fastened
with two screws per corner.
Sash
Construction : The sash was constructed
of extruded aluminum members that employed a
poured-in-place urethane thermal break. The
corners were straight cut, sealed and fastened
with two screws per corner.
Screen
Construction : The screen was constructed
of extruded aluminum members and the corners
were keyed and staked. The screen mesh was held-in-place
with flexible spline.
| Hardware |
| Description |
Quantity |
Location |
| Metal cam sweep locks with
keepers |
2 |
13'' o.c. from ends of interior
meeting rail with keepers aligned on exterior
meeting rail |
| Block & tackle balance |
8 |
Four per jamb |
| Drainage |
| Description |
Quantity |
Location |
| Sloped sill |
1 |
Sill |
| Installation |
The test
unit was secured to the 2'' x 10'' wood
test frame with ten screws per jamb. Two
per sash track, 2-¼''from jamb ends and
evenly spaced thereafter. The test unit
was also blind stopped to the interior and
exterior perimeter with wood stops and was
sealed with silicone |
Test Results
The results are tabulated as follows:
| Paragraph |
Title of Test - Test Method |
Results |
Allowed |
| 2.2.1.6.1 |
Operating Force |
43 lbs |
43 lbs max |
| 2.1.2 |
Air Infiltration per ASTM
E 283 (See note # 1) @ 1.57 psf (25 mph)
|
0.16 cfm/ft2 |
0.30 cfm/ft2 max |
| Note # 1 |
The tested specimen meets
(or exceeds) the performance levels specified
in AAMA/NWWDA 101/I.S. 2-97 for air infiltration |
| 2.1.3 |
Water Resistance per ASTM
E 547(with and without screen)WTP = 4.50
psf |
|
|
| 2.1.4.2 |
Uniform Load Structural(Measurements
reported were taken on the meeting rail
and bottom rail) |
|
|
| |
@
45.0 psf (exterior) |
0.008'' |
0.210''
max. |
| |
@
45.0 psf (interior) |
0.005" |
0.210''
max. |
| 2.2.1.6.2 |
Deglazing Test per ASTM E
987In operating direction at 70 lbs |
|
|
| |
Top rail |
0.040"/8% |
0.500"/100% |
| |
Exterior meeting
rail |
0.060"/12% |
0.500"/100% |
| |
Interior meeting rail |
0.050"/10% |
0.500"/100% |
| |
Bottom rail |
0.030"/6% |
0.500"/100% |
| |
In remaining direction at
50 lbs |
|
|
| |
Exterior left stile |
0.070"/14% |
0.500"/100% |
| |
Exterior right stile |
0.050"/10% |
0.500"/100% |
| |
Interior left side |
0.050"/10% |
0.500"/100% |
| |
Interior right stile |
0.030"/6% |
0.500"/100% |
| 2.1.8 |
Forced Entry Resistance per
ASTM F 588-97 |
| |
Type: A |
|
|
| |
Grade: 10 |
|
|
| |
Lock Manipulation Test |
No entry |
No entry |
| |
Test A1 through A7 |
No entry |
No entry |
| |
Lock Manipulation Test |
No entry |
No entry |
| Optional
Performance |
| Paragraph |
Title of Test - Test Method |
Results |
Allowed |
| 4.3 |
Water Resistance per ASTM
E 331 and ASTM E 547 (with and without screen)
|
| |
WTP = 8.25 psf |
No leakage |
No leakage |
| 4.4.2 |
Uniform Load Structural (Measurments
reported were taken on the meeting rail
and bottom rail) |
| |
@ 82.50 psf (exterior) |
0.070" |
0.210" max |
| |
@ 82.50 psf (interior) |
0.015" |
0.210" max |
Detailed
drawings, representative samples of the test
specimen and a copy of this report will be retained
by AT1 for a period of four years. The above
results were secured by using the designated
test methods and they indicate compliance with
the performance requirements of the above referenced
specification. This report does not constitute
certification of this product, which may only
be granted by the certification program administrator.
For ARCHITECTURAL
TESTING INC.
| Scott D. Kramer |
Bruce W. Croak |
| Technician |
Director of Structural Testing |
SDK:nlb
01-34654.01
|