1290 SIDELOAD SERIES - TEST REPORT
CLICK HERE FOR 1290 SERIES - SPECIFICATIONS
CLICK HERE FOR 1290 SERIES - DRAWING 3000 Tilt 1290 SideLoad

AAMA/NWWDA 101/I.S.2-97 TEST REPORT

Rendered to:

REPCO
510 Station Avenue
Bensalem, Pennsylvania 19020

Report No: 01-34654.01
Test Date: 05/04/99
Report Date: 06/07/99
Expiration Date: 05/04/03


Project Summary

Architectural Testing Inc. (ATI) was contracted to perform tests on a Series/Model 1290, aluminum double hung window. The sample tested successfully met the performance requirements for a H-C55 54 x 90 rating. Test specimen description and results are reported herein.

Test Specification

AAMA/NWWDA 101/I.S.2-97, Voluntary Specification for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors.

Test Specimen Description  
Series/Model 1290
Type Aluminum Double Hung Window (Side-Load)
Overall Size 4'6-¼'' wide by 7'8-¼'' high
Interior Sash Size 4'4'' wide by 3'9-1/8'' high
Exterior Sash Size 4'4'' wide by 3'9-1/8'' high
Screen Size 4'4'' wide by 3'9'' high
Finish All aluminum was painted brown
Glazing Details Both sashes utilized 7/8"" thick insulating glass fabricated from two sheets of 1/8'' thick clear annealed glass and a desiccant filled metal spacer system. The insulating glass was channel glazed utilizing a flexible wedge gasket.

Weatherstripping
Description Quantity Location
0.170'' high by 0.187''backed polypile with center fin 1 Row Head, still and stiles
0.310'' high by 0.187''backed polypile with center fin 1 Row Interior meeting rail
0.350'' diameter custom hollow vinyl bulb seal 1 Row Bottom rail

Frame Construction : The frame was constructed of extruded aluminum members that employed a poured-in-place urethane thermal break. The corners were coped, butted, sealed and fastened with two screws per corner.

Sash Construction : The sash was constructed of extruded aluminum members that employed a poured-in-place urethane thermal break. The corners were straight cut, sealed and fastened with two screws per corner.

Screen Construction : The screen was constructed of extruded aluminum members and the corners were keyed and staked. The screen mesh was held-in-place with flexible spline.

Hardware
Description Quantity Location
Metal cam sweep locks with keepers 2 13'' o.c. from ends of interior meeting rail with keepers aligned on exterior meeting rail
Block & tackle balance 8 Four per jamb
Drainage
Description Quantity Location
Sloped sill 1 Sill
Installation The test unit was secured to the 2'' x 10'' wood test frame with ten screws per jamb. Two per sash track, 2-¼''from jamb ends and evenly spaced thereafter. The test unit was also blind stopped to the interior and exterior perimeter with wood stops and was sealed with silicone

Test Results
The results are tabulated as follows:

Paragraph Title of Test - Test Method Results Allowed
2.2.1.6.1 Operating Force 43 lbs 43 lbs max
2.1.2 Air Infiltration per ASTM E 283 (See note # 1) @ 1.57 psf (25 mph) 0.16 cfm/ft2 0.30 cfm/ft2 max
Note # 1 The tested specimen meets (or exceeds) the performance levels specified in AAMA/NWWDA 101/I.S. 2-97 for air infiltration
2.1.3 Water Resistance per ASTM E 547(with and without screen)WTP = 4.50 psf    
2.1.4.2 Uniform Load Structural(Measurements reported were taken on the meeting rail and bottom rail)    
  @ 45.0 psf (exterior) 0.008'' 0.210'' max.
  @ 45.0 psf (interior) 0.005" 0.210'' max.
2.2.1.6.2 Deglazing Test per ASTM E 987In operating direction at 70 lbs    
  Top rail 0.040"/8% 0.500"/100%
  Exterior meeting rail 0.060"/12% 0.500"/100%
  Interior meeting rail 0.050"/10% 0.500"/100%
  Bottom rail 0.030"/6% 0.500"/100%
  In remaining direction at 50 lbs    
  Exterior left stile 0.070"/14% 0.500"/100%
  Exterior right stile 0.050"/10% 0.500"/100%
  Interior left side 0.050"/10% 0.500"/100%
  Interior right stile 0.030"/6% 0.500"/100%
2.1.8 Forced Entry Resistance per ASTM F 588-97
  Type: A    
  Grade: 10    
  Lock Manipulation Test No entry No entry
  Test A1 through A7 No entry No entry
  Lock Manipulation Test No entry No entry

 

Optional Performance
Paragraph Title of Test - Test Method Results Allowed
4.3 Water Resistance per ASTM E 331 and ASTM E 547 (with and without screen)
  WTP = 8.25 psf No leakage No leakage
4.4.2 Uniform Load Structural (Measurments reported were taken on the meeting rail and bottom rail)
  @ 82.50 psf (exterior) 0.070" 0.210" max
  @ 82.50 psf (interior) 0.015" 0.210" max

Detailed drawings, representative samples of the test specimen and a copy of this report will be retained by AT1 for a period of four years. The above results were secured by using the designated test methods and they indicate compliance with the performance requirements of the above referenced specification. This report does not constitute certification of this product, which may only be granted by the certification program administrator.

For ARCHITECTURAL TESTING INC.

Scott D. Kramer Bruce W. Croak
Technician Director of Structural Testing

SDK:nlb
01-34654.01

 

 
aluminum commercial | installation/accessories | project portfolio | architects | contact us | home
111 Central Avenue  Teterboro, NJ 07608
Toll Free: 1.800.888.7590
Fax: 201.943.1282