2290 HC SIDELOAD SERIES - TEST REPORT
CLICK HERE FOR 2290 HC SIDELOAD SERIES - SPECIFICATIONS
CLICK HERE FOR 2290 HC SIDELOAD SERIES - DRAWING
3000 Tilt 1290 SideLoad
 

STRUCTURAL TEST REPORT

Rendered to:

REPCO
510 Station Avenue
Bensalem, Pennsylvania 19020

Report No: ATI-19359
Test Date: 02/13/97
Thru: 04/03/97
Report Date: 04/14/97
Revised Report Date: 05/08/97
Expiration Date: 02/13/01


Series/Model: 2290 HC

Type Aluminum Double Hung Window (Sideload)

Project Summary

Architectural Testing Inc. (ATI) was contracted to perform tests on a 2290 HC Series aluminum double hung window (sideload) manufactured by Repco. The specimen tested met all of the performance criteria for an H-HC50 rating in accordance with AAMA/NWWDA 101/I"S" 2-97 and a Level 10 forced entry resistance rating in accordance with ASTM F588-85. The following report includes a detailed test specimen description, test data and results.

Test Procedure: The test specimen was evaluated in accordance with:

  • AAMA/NWWDA 101/I.S.2-97, Voluntary Specification for Aluminum, Vinyl (PVC) and Wood Windows.
  • ASTM F588-85, Standard Test Methods of Resistance of Window Assemblies to Forced Entry Excluding Glazing.
Test Specimen Description
Overall Size 5'0" wide by 8'0" high
Interior Sash Size 4' 10-1/2" wide by 3' 11-3/4" high
Exterior Sash Size 4' 10-1/2" wide by 3' 11-3/4" high
Screen Size 4' 9-1/2" wide by 4'0" high
Finish Aluminum was painted bronze
Glazing Both sashes utilized 7/8'' thick sealed insulating glass that was comprised of tow 1/8'' thick clear sheets of annealed glass and a desiccant-filled metal spacer system. The sealed insulating glass was channel glazed employing a flexible wedge gasket.

Weatherstripping
Description Quantity Location
0.187" backed by 0.075" high rigid vinyl 1 Row Length of interior sash stiles on interior face and exterior sash stiles on exterior face
0.187'' backed by 0.170''high center fin poly pile 1 Row Length of still interior vertical leg, interior sash stiles on exterior face, exterior sash stiles on interior face and head intermediate and exterior legs
0.187'' backed by 0.310''high center fin poly pile 1 Row Length of interior sash meeting rail on exterior face inserted in plastic hollow cover
0.187'' backed by 0.500''high hollow flexible bulb gasket 1 Row Length of interior sash bottom rail
0.187'' backed by 0.330''high poly pile 1 Row Length of screen top rail

Frame Construction : The frame was constructed of extruded aluminum members that incorporated a poured-in-place urethane thermal break with an average debridged width of 0.135''. All corners were coped, butted, sealed and fastened with two screws per corner.

Sash Construction : Both sashes were constructed of extruded aluminum members that incorporated a poured-in-place urethane thermal break with an average debridged width of 0.135''. All corners were coped, butted, sealed and fastened with two screws per corner. A 0.052'' thick ''J'' shaped extruded aluminum reinforcement member was located inside the exterior sash meeting rail hollow.

Screen Construction : The screen was constructed of extruded aluminum members. All corners were mitered, staked and keyed. The screen mesh was held in place with a flexible spline.

Hardware
Description Quantity Location
Spring-loaded block and tacle balances 6 Three balances per sash
Metal cam locks 2 One located 12" from each end of interior sash meeting rail
Keepers 2 Opposite locks on exterior sash meeting rail
Custom plastic meeting rail insert 2 Installed at ends of exterior sash meeting rail
Drainage : Sloped sill    

Test Results
The results are tabulated as follows:

Paragraph Title of Test Results Allowed
2.2.1.6.1 Operating Force 44 lbs 45 lbs max
Note: Operating force results were obtained with silicone lubricant applied at the jamb pockets
2.1.2 Air Infiltration    
  @ 0.56 psf (15 mph) 0.09 cfm/ft2 ---
  @ 1.56 psf (25 mph) 0.17 cfm/ft2 0.30 cfm/ft2 max
2.1.3 Water Resistance (with and without screen)    
  WTP = 6.00 psf No entry No entry
  @ 5.00 gph/ft2    
2.1.4.1 Uniform Load Structural (with 3/16" annealed glass)    
  @ 40.0 psf (exterior) 0.295" 0.325" max
  @ 50.0 psf (interior) 0.000" 0.114" max
2.1.5 Forced Entry Resistance (ASTM F588-85)
  Hand Manipulation No entry No entry
  Tool Manipulation No entry No entry
  Test 1 No entry No entry
  Test 2 No entry No entry
  Test 3 No entry No entry
  Test 4 No entry No entry
  Test 5 No entry No entry
  Test 6 No entry No entry
  Test 7 No entry No entry
  Hand Manipulation No entry No entry
  Tool Manipulation No entry No entry
2.2.1.6.2 Deglazing Test    
  In operating direction at 70 lbs    
  Interior sash bottom rail 0.075"/15% 0.500"/100%
  Inetrior sash meeting rail 0.080"/16% 0.500"/100%
  Exterior sash meeting rail 0.080"/16% 0.500"/100%
  Exterior sash top rail 0.090"/18% 0.500"/100%
  Interior sash left stile 0.030"/6% 0.500"/100%
  Interior sash right stile 0.040"/8% 0.500"/100%
  Exterior sash left stile 0.060"/12% 0.500"/100%
  Exterior sash right stile 0.020"/4% 0.500"/100%
Optional Performance
Paragraph Title of Test - Test Method Results Allowed
4.3 Water Resistance (with and without screen)
  WTP = 7.50 psf No entry No entry
  @5.00 gph/ft2    
4.4.1 Uniform Load Deflection Test (with 3/16" annealed glass)
  @ 50.0 psf (exterior) 0.305" 0.325" max
  @50.0 psf (interior) 0.305" 0.325" max
4.4.2 Uniform Load Structural Test (with 3/16" annealed glass)
  @ 75.0 psf (exterior) 0.000" 0.114" max
  @ 75.0 psf (interior) 0.000" 0.114" max

Detailed drawings, representative samples of the test specimen and a copy of this report will be retained by AT1 for a period of four years. The above results were secured by using the designated test methods and they indicate compliance with the performance requirements of the above referenced specification. This report does not constitute certification of this product, which may only be granted by the certification program administrator.

For ARCHITECTURAL TESTING INC.

Eric C. Rock Bruce W. Croak
Technician Project Manager

ECR:cat
19359

 

 
aluminum commercial | installation/accessories | project portfolio | architects | contact us | home
111 Central Avenue  Teterboro, NJ 07608
Toll Free: 1.800.888.7590
Fax: 201.943.1282