STRUCTURAL
TEST REPORT
Rendered to:
REPCO
510 Station Avenue
Bensalem, Pennsylvania 19020
Report No: ATI-19359
Test Date: 02/13/97
Thru: 04/03/97
Report Date: 04/14/97
Revised Report Date: 05/08/97
Expiration Date: 02/13/01
Series/Model: 2290 HC
Type
Aluminum Double Hung Window (Sideload)
Project
Summary
Architectural
Testing Inc. (ATI) was contracted to perform
tests on a 2290 HC Series aluminum double hung
window (sideload) manufactured by Repco. The
specimen tested met all of the performance criteria
for an H-HC50 rating in accordance with AAMA/NWWDA
101/I"S" 2-97 and a Level 10 forced entry resistance
rating in accordance with ASTM F588-85. The
following report includes a detailed test specimen
description, test data and results.
Test
Procedure: The test specimen was evaluated
in accordance with:
- AAMA/NWWDA 101/I.S.2-97,
Voluntary Specification for Aluminum, Vinyl
(PVC) and Wood Windows.
- ASTM F588-85, Standard Test
Methods of Resistance of Window Assemblies
to Forced Entry Excluding Glazing.
| Test Specimen
Description |
| Overall Size |
5'0" wide by 8'0"
high |
| Interior Sash Size |
4' 10-1/2" wide by 3'
11-3/4" high |
| Exterior Sash Size |
4' 10-1/2" wide by 3'
11-3/4" high |
| Screen Size |
4' 9-1/2" wide by 4'0"
high |
| Finish |
Aluminum was painted bronze
|
| Glazing |
Both sashes utilized 7/8''
thick sealed insulating glass that was comprised
of tow 1/8'' thick clear sheets of annealed
glass and a desiccant-filled metal spacer
system. The sealed insulating glass was
channel glazed employing a flexible wedge
gasket. |
| Weatherstripping |
| Description |
Quantity |
Location |
| 0.187" backed
by 0.075" high rigid vinyl |
1 Row |
Length of interior
sash stiles on interior face and exterior
sash stiles on exterior face |
| 0.187'' backed by 0.170''high
center fin poly pile |
1 Row |
Length of still interior vertical
leg, interior sash stiles on exterior face,
exterior sash stiles on interior face and
head intermediate and exterior legs |
| 0.187'' backed by 0.310''high
center fin poly pile |
1 Row |
Length of interior sash meeting
rail on exterior face inserted in plastic
hollow cover |
| 0.187'' backed by 0.500''high
hollow flexible bulb gasket |
1 Row |
Length of interior sash bottom
rail |
| 0.187'' backed by 0.330''high
poly pile |
1 Row |
Length of screen top rail |
Frame Construction
: The frame was constructed of extruded
aluminum members that incorporated a poured-in-place
urethane thermal break with an average debridged
width of 0.135''. All corners were coped, butted,
sealed and fastened with two screws per corner.
Sash Construction
: Both sashes were constructed of extruded
aluminum members that incorporated a poured-in-place
urethane thermal break with an average debridged
width of 0.135''. All corners were coped, butted,
sealed and fastened with two screws per corner.
A 0.052'' thick ''J'' shaped extruded aluminum
reinforcement member was located inside the
exterior sash meeting rail hollow.
Screen Construction
: The screen was constructed of extruded
aluminum members. All corners were mitered,
staked and keyed. The screen mesh was held in
place with a flexible spline.
| Hardware |
| Description |
Quantity |
Location |
| Spring-loaded block and tacle
balances |
6 |
Three balances per sash |
| Metal cam locks |
2 |
One located 12" from
each end of interior sash meeting rail |
| Keepers |
2 |
Opposite locks on exterior
sash meeting rail |
| Custom plastic meeting rail
insert |
2 |
Installed at ends of exterior
sash meeting rail |
| Drainage : Sloped sill |
|
|
Test Results
The results are tabulated as follows:
| Paragraph |
Title of Test |
Results |
Allowed |
| 2.2.1.6.1 |
Operating Force |
44 lbs |
45 lbs max |
| Note: Operating
force results were obtained with silicone
lubricant applied at the jamb pockets |
| 2.1.2 |
Air Infiltration |
|
|
| |
@ 0.56 psf (15 mph) |
0.09 cfm/ft2 |
--- |
| |
@ 1.56 psf (25 mph) |
0.17 cfm/ft2 |
0.30 cfm/ft2 max |
| 2.1.3 |
Water Resistance (with and
without screen) |
|
|
| |
WTP = 6.00 psf |
No entry |
No entry |
| |
@ 5.00 gph/ft2 |
|
|
| 2.1.4.1 |
Uniform Load Structural (with
3/16" annealed glass) |
|
|
| |
@ 40.0 psf (exterior) |
0.295" |
0.325" max |
| |
@ 50.0 psf (interior) |
0.000" |
0.114" max |
| 2.1.5 |
Forced Entry Resistance (ASTM
F588-85) |
| |
Hand Manipulation |
No entry |
No entry |
| |
Tool Manipulation |
No entry |
No entry |
| |
Test 1 |
No entry |
No entry |
| |
Test 2 |
No entry |
No entry |
| |
Test 3 |
No entry |
No entry |
| |
Test 4 |
No entry |
No entry |
| |
Test 5 |
No entry |
No entry |
| |
Test 6 |
No entry |
No entry |
| |
Test 7 |
No entry |
No entry |
| |
Hand Manipulation |
No entry |
No entry |
| |
Tool Manipulation |
No entry |
No entry |
| 2.2.1.6.2 |
Deglazing Test |
|
|
| |
In operating direction at
70 lbs |
|
|
| |
Interior sash bottom rail
|
0.075"/15% |
0.500"/100% |
| |
Inetrior sash meeting rail
|
0.080"/16% |
0.500"/100% |
| |
Exterior sash
meeting rail |
0.080"/16% |
0.500"/100% |
| |
Exterior sash top rail |
0.090"/18% |
0.500"/100% |
| |
Interior sash left stile |
0.030"/6% |
0.500"/100% |
| |
Interior sash right stile
|
0.040"/8% |
0.500"/100% |
| |
Exterior sash
left stile |
0.060"/12% |
0.500"/100% |
| |
Exterior sash right stile
|
0.020"/4% |
0.500"/100% |
| Optional
Performance |
| Paragraph |
Title of Test - Test Method |
Results |
Allowed |
| 4.3 |
Water Resistance (with and
without screen) |
| |
WTP = 7.50 psf |
No entry |
No entry |
| |
@5.00 gph/ft2 |
|
|
| 4.4.1 |
Uniform Load Deflection Test
(with 3/16" annealed glass) |
| |
@ 50.0 psf (exterior) |
0.305" |
0.325" max |
| |
@50.0 psf (interior) |
0.305" |
0.325" max |
| 4.4.2 |
Uniform Load Structural Test
(with 3/16" annealed glass) |
| |
@ 75.0 psf (exterior) |
0.000" |
0.114" max |
| |
@ 75.0 psf (interior) |
0.000" |
0.114" max |
Detailed drawings, representative
samples of the test specimen and a copy of this
report will be retained by AT1 for a period
of four years. The above results were secured
by using the designated test methods and they
indicate compliance with the performance requirements
of the above referenced specification. This
report does not constitute certification of
this product, which may only be granted by the
certification program administrator.
For ARCHITECTURAL
TESTING INC.
| Eric C. Rock |
Bruce W. Croak |
| Technician |
Project Manager |
ECR:cat
19359
|