3000 Tilt 1290 SideLoad 3000 TILT SERIES - TEST REPORT
CLICK HERE FOR 3000 TILT SERIES - SPECIFICATIONS
CLICK HERE FOR 3000 TILT SERIES - DRAWING

AAMA/NWWDA 101/I.S.2-97 TEST REPORT

Rendered to:

REPCO
510 Station Avenue
Bensalem, Pennsylvania 19020

Report No: 01-35627.01
Test Date: 01/19/00
Report Date: 02/03/00
Expiration Date: 01/09/04

Project Summary

Architectural Testing Inc. (ATI) was contracted to perform tests on a Series/Model 3000, aluminum double hung window. The sample tested successfully met the performance requirements for a H-C50 54 x 90 rating. Test specimen description and results are reported herein.

Test Specification

The test specimen was evaluated in accordance with AAMA/NWWDA 101/I.S.2-97, Voluntary Specification for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors.

Test Specimen Description

Series/Model 3000
Type Aluminum Double Hung Window
Overall Size 4'6-¼'' wide by 3'8- ½'' high
Interior Sash Size 4'3- 3/8'' wide by 3'8-½'' high
Exterior Sash Size 4'2-½'' wide by 3'8-5/8'' high
Screen Size 4'4-¼'' wide by 3'9'' high
Finish All aluminum was painted bronze
Glazing Details The exterior sash utilized 13/16'' thick sealed insulating glass fabricated from two sheets of 3/32'' thick clear annealed glass and a desiccant filled metal spacer system. The insulating glass was channel glazed in a flexible wedge gasket. The interior sash utilized 7/8'' thick sealed insulating glass fabricated from two sheets of 1/8'' thick clear annealed glass. All other glazing aspects are the same as above.

Weatherstripping :

Description Quantity Location
0.250'' high by 0.187'' backed polypile with center fin 2 Rows All stiles, interior meeting rail
0.250'' high by 0.187''backed polypile with center fin 1 Row Top rail and head
¼'' diameter hollow vinyl bulb seal 2 Rows Bottom rail


Frame Construction : The frame was constructed of extruded aluminum members that employed a urethane thermal break. All corners were coped, butted, sealed and fastened with two screws per corner. The sill extrusion was reinforced with a tooled plywood insert that seated up in the extrusion. The jambs utilized a rigid vinyl sash tract stiffener.

Sash Construction : The sash was constructed of extruded aluminum members that employed a urethane thermal break. All corners were coped, butted, sealed and fastened with two screws per corner.

Screen Construction : The screen was constructed of extruded aluminum members and all corners were keyed. The screen mesh was held-in-place with flexible spline.

Hardware :

Description Quantity Location
Metal sweep lock 2 13'' o.c. from ends of interior meeting rail
Plastic tilt latch 4 Ends of top rail and interior meeting rail
Metal pivot pins 4 Ends of bottom rail and exterior meeting rail

Drainage :

Description Quantity Location
Sloped sill    
Reinforcement : The exterior meeting rail was reinforced with an extruded aluminum insert with an average 0.175'' thickness.
Installation : The window was secured to the 2'' x 8'' wood test buck with ten screws per jamb. The exterior perimeter was sealed with silicone.

Test Results:
The results are tabulated as follows:

Paragraph Title of test - Test Method Results Allowed
2.2.1.6.1 Operating Force 41 lbs. 45 lbs. Max.
2.1.2 Air Infiltration per ASTM E 283 (See Note #1) @
  1.57 psf (25 mph) 0.20 cfm/ft 0.30 cfm/ft max.
Note #1: The tested specimen meets (or exceeds) the performance levels specified in AAMA/NWWDA 101/I.S 2-97 for air infiltration
2.1.3 Water Resistance per ASTM E 547 (with and without screen)
  WTP = 4.50 psf No Leakage No Leakage
2.1.4.2 Uniform Load Structural per ASTM E 330 (Measurement reported were taken on the meeting rail)
  @ 45.0 psf (exterior) 0.01" 0.20" max
  @ 45.0 psf (interior) 0.02" 0.20" max
2.2.1.6.2 Deglazing Test per ASTM E 987 In operating direction at 70 lbs.
  Top Rail 0.04"/8% 0.500"/100%
  Exterior meeting rail 0.06"/12% 0.500"/100%
  Interior meeting rail 0.02"/4% 0.500"/100%
  Bottom rail 0.04"/8% 0.500"/100%
In remaining direction at 50 lbs.
  Exterior left stile 0.03"/6% 0.500"/100%
  Exterior right stile 0.03"/6% 0.500"/100%
  Interior right stile 0.04"/8% 0.500"/100%
  Interior right stile 0.6"/12% 0.500"/100%
2.1.8 Forced Entry Resistance per ASTM F 588-97
  Type : A    
  Grade : 10    
  Lock Manipulation Test No entry No entry
  Tests A1 thru A7 No entry No entry
  Lock Manipulation Test No entry No entry
Optional Performance
4.3 Water Resistance per ASTM E 547 (with and without screen)
  WTP = 7.50 psf No leakage No leakage
4.4.2 Uniform Load Structural per ASTM E 330 (Measurements reported were taken on the meeting rail)
  @ 75.0 psf (exterior) 0.02" 0.20" max
  @ 75.0 psf (interior) 0.03" 0.20" max
       
       

Detailed drawings, representative samples of the test specimen and a copy of this report will be retained by AT1 for a period of four years. The above results were secured by using the designated test methods and they indicate compliance with the performance requirements of the above referenced specification. This report does not constitute certification of this product, which may only be granted by the certification program administrator.

For ARCHITECTURAL TESTING INC.

Scott D. Kramer Bruce W. Croak
Technician Director of Structural Testing

SDK:nlb
01-35627.01

 
aluminum commercial | installation/accessories | project portfolio | architects | contact us | home
111 Central Avenue  Teterboro, NJ 07608
Toll Free: 1.800.888.7590
Fax: 201.943.1282