AAMA/NWWDA
101/I.S.2-97 TEST REPORT
Rendered
to:
REPCO
510 Station Avenue
Bensalem, Pennsylvania 19020
Report No: 01-35627.01
Test Date: 01/19/00
Report Date: 02/03/00
Expiration Date: 01/09/04
Project
Summary
Architectural Testing Inc.
(ATI) was contracted to perform tests on a Series/Model
3000, aluminum double hung window. The sample
tested successfully met the performance requirements
for a H-C50 54 x 90 rating. Test specimen description
and results are reported herein.
Test
Specification
The test
specimen was evaluated in accordance with AAMA/NWWDA
101/I.S.2-97, Voluntary Specification for Aluminum,
Vinyl (PVC) and Wood Windows and Glass Doors.
Test
Specimen Description
| Series/Model |
3000 |
| Type |
Aluminum Double Hung Window |
| Overall Size |
4'6-¼'' wide by 3'8- ½'' high |
| Interior Sash Size |
4'3- 3/8'' wide by 3'8-½''
high |
| Exterior Sash Size |
4'2-½'' wide by 3'8-5/8''
high |
| Screen Size |
4'4-¼'' wide by 3'9'' high |
| Finish |
All aluminum was painted bronze |
| Glazing Details |
The exterior sash utilized
13/16'' thick sealed insulating glass fabricated
from two sheets of 3/32'' thick clear annealed
glass and a desiccant filled metal spacer
system. The insulating glass was channel
glazed in a flexible wedge gasket. The interior
sash utilized 7/8'' thick sealed insulating
glass fabricated from two sheets of 1/8''
thick clear annealed glass. All other glazing
aspects are the same as above. |
Weatherstripping
:
| Description |
Quantity |
Location |
| 0.250'' high by 0.187'' backed polypile
with center fin |
2 Rows |
All stiles, interior meeting rail |
| 0.250'' high by 0.187''backed polypile
with center fin |
1 Row |
Top rail and head |
| ¼'' diameter hollow vinyl bulb seal |
2 Rows |
Bottom rail |
Frame Construction :
The frame was constructed of extruded aluminum
members that employed a urethane thermal break.
All corners were coped, butted, sealed and fastened
with two screws per corner. The sill extrusion
was reinforced with a tooled plywood insert
that seated up in the extrusion. The jambs utilized
a rigid vinyl sash tract stiffener.
Sash
Construction : The sash was constructed
of extruded aluminum members that employed a
urethane thermal break. All corners were coped,
butted, sealed and fastened with two screws
per corner.
Screen
Construction : The screen was constructed
of extruded aluminum members and all corners
were keyed. The screen mesh was held-in-place
with flexible spline.
Hardware
:
| Description |
Quantity |
Location |
| Metal sweep lock |
2 |
13'' o.c. from ends of interior meeting
rail |
| Plastic tilt latch |
4 |
Ends of top rail and interior meeting
rail |
| Metal pivot pins |
4 |
Ends of bottom rail and exterior meeting
rail |
Drainage :
| Description |
Quantity |
Location |
| Sloped sill |
|
|
| Reinforcement : |
The exterior meeting rail
was reinforced with an extruded aluminum
insert with an average 0.175'' thickness. |
| Installation : |
The window was secured to
the 2'' x 8'' wood test buck with ten screws
per jamb. The exterior perimeter was sealed
with silicone. |
Test Results:
The results are tabulated as follows:
| Paragraph |
Title of test - Test Method |
Results |
Allowed |
| 2.2.1.6.1 |
Operating Force |
41 lbs. |
45 lbs. Max. |
| 2.1.2 |
Air Infiltration per ASTM
E 283 (See Note #1) @ |
| |
1.57 psf (25 mph) |
0.20 cfm/ft |
0.30 cfm/ft max. |
| Note #1:
The tested specimen meets (or exceeds) the
performance levels specified in AAMA/NWWDA
101/I.S 2-97 for air infiltration |
| 2.1.3 |
Water Resistance per ASTM
E 547 (with and without screen) |
| |
WTP = 4.50 psf |
No Leakage |
No Leakage |
| 2.1.4.2 |
Uniform Load Structural per
ASTM E 330 (Measurement reported were taken
on the meeting rail) |
| |
@ 45.0 psf (exterior) |
0.01" |
0.20" max |
| |
@ 45.0 psf (interior) |
0.02" |
0.20" max |
| 2.2.1.6.2 |
Deglazing Test per ASTM E
987 In operating direction at 70 lbs. |
| |
Top Rail |
0.04"/8% |
0.500"/100% |
| |
Exterior meeting rail |
0.06"/12% |
0.500"/100% |
| |
Interior meeting rail |
0.02"/4% |
0.500"/100% |
| |
Bottom rail |
0.04"/8% |
0.500"/100% |
| In remaining
direction at 50 lbs. |
| |
Exterior left stile |
0.03"/6% |
0.500"/100% |
| |
Exterior right stile |
0.03"/6% |
0.500"/100% |
| |
Interior right stile |
0.04"/8% |
0.500"/100% |
| |
Interior right stile |
0.6"/12% |
0.500"/100% |
| 2.1.8 |
Forced Entry Resistance per
ASTM F 588-97 |
| |
Type : A |
|
|
| |
Grade : 10 |
|
|
| |
Lock Manipulation Test |
No entry |
No entry |
| |
Tests A1 thru A7 |
No entry |
No entry |
| |
Lock Manipulation Test |
No entry |
No entry |
| Optional
Performance |
| 4.3 |
Water Resistance per ASTM
E 547 (with and without screen)
|
| |
WTP = 7.50 psf |
No leakage |
No leakage |
| 4.4.2 |
Uniform Load
Structural per ASTM E 330 (Measurements
reported were taken on the meeting rail)
|
| |
@ 75.0 psf (exterior) |
0.02" |
0.20" max |
| |
@ 75.0 psf (interior) |
0.03" |
0.20" max |
| |
|
|
|
| |
|
|
|
Detailed
drawings, representative samples of the test
specimen and a copy of this report will be retained
by AT1 for a period of four years. The above
results were secured by using the designated
test methods and they indicate compliance with
the performance requirements of the above referenced
specification. This report does not constitute
certification of this product, which may only
be granted by the certification program administrator.
For ARCHITECTURAL
TESTING INC.
| Scott D. Kramer |
Bruce W. Croak |
| Technician |
Director of Structural Testing |
SDK:nlb
01-35627.01
|