SECTION 08520-ALUMINUM WINDOWS
1.1.1 SCOPE. All aluminum
windows of the types and sizes shown in the plans
and/or as called for in this specification shall be
furnished with all the necessary hardware, anchors,
and miscellaneous equipment as herein specified, and
shall be manufactured by Repco Replacement Products
Industries Corporation or equal.
1.2.1 ALLOYS. Aluminum
shall be of commercial quality and of proper alloy
for window construction free from defects impairing
strength and durability. All extruded sections shall
be of 6063-T5 or 6060-T5 alloy tempers, and shall
have a minimum ultimate tensile strength of 22,000
P.S.I. and a yield of 16,000 P.S.I.
1.2.2 WINDOW MEMBERS.
Mainframe and sash members shall have a nominal wall
thickness of not less then .062" except for fin
trim either integral or applied. Frame sill members
shall have a nominal wall thickness of 0,078".
The standard wall thickness tolerances as defined
by the Aluminum Association shall apply. The master
frame shall be no less than 3 1/4" in depth.
1.2.3 FASTENERS. All
screws and other miscellaneous fastening devices Incorporated
In the product shall be of aluminum, stainless steel,
or other non-corrosive material compatible with aluminum.
Cadmium or zinc plated steel, where used, shall be
in accordance with ASTM A165 or B633. Nickel or chrome
plated steel, where used, shall be in accordance with
ASTM B-456-79.
1.2.4 HARDWARE. Hardware
having component parts, which are exposed, shall be
of aluminum, stainless steel, or other no corrosive
material compatible with aluminum. Cadmium or zinc
plated steel where used. Must be in accordance with
ASTM Specifications A 164-71 or A 165-71.
1.2.5 ROLLING MECHANISMS.
A metal roller/plastic housing is located at each
end of both panel bottom rail. A rigid vinyl roller
track is snap-fitted at the interior sill track.
1.2.6 WEATHERSTRIPPING.
All window units shall be weather stripped with a
jacketed foam type weather-stripping or pile type
weather-stripping with center fin so that there is
no metal-to-metal contact between the master frame
and the operating sash. All weather-stripping shall
be Installed in specially extruded ports and secured
to prevent movement, shrinkage, or loss when removing
sash for either cleaning or repair and during normal
sash operation. Jacketed foam weather-stripping, where
used, must conform to AAMA Specification 701.2.
1.3.1 ASSEMBLY. The
windows shall be assembled in a workman like manner
to perform as herein specified and to assure neat
and weather tight construction.
1.3.2 MAIN FRAME. All
joints of the main frame shall be butt type construction
and secured by means of two (2) screws in each corner
anchored In integral screw ports, The main frame at
the junction of the sill and jamb shall be sealed
on the outside with a good grade of sealant meeting
the requirements of AAMA 803.3.
1.3.3 SASHES. Both the
sashes shall be operational and sash members shall
be of butt type joined at corners with screws in Integral
screw ports, which can be easily removed for repair
or re-glazing. The meeting rails of both sashes shall
interlock in the closed position.
1.3.4 THERMAL BARRIER.
All main frame and sash members shall be thermally
broken by poured and debridged method and shall have
a 3/16"minimum thermal separation. The thermal
barrier material shall be a polyurethane fill with
ultimate tensile strength to meet or exceed ASTM Specification
D-638.
1.3.5 GLASS. Glass shall
not be less than 'B" quality and "DSB",
shall conform to FS DD-G-451 D. Standard factory glazing
shall be DSB 7/8" inch insulating glass, or as
specified. Sealed insulating where used, shall meet
SIGMA No, 65-7-2 and be of at least "A' quality.
Safety glazing materials, where used, shall meet ANSI
Z-97. Tempered glazing, where used, shall meet ASTM
C 1048.
1.3.6 GLAZING MATERIAL
Glass shall be set in channel type vinyl gaskets (marine
glazed). Vinyl shall be of materials compatible with
ALUMINUM which will not promote corrosion and shall
be resistant to deterioration by all forms of weathering
and shall be suitably retained to maintain a watertight
sea] between the glass and its surrounding frame.
Flexible vinyl, where used, shall be equal to Commercial
Standard CS230-60. Drop in glazing will not be acceptable.
1.3.7 FINISH. The exposed
surfaces of all aluminum members shall be dean and
free from serious surface blemishes. Standard finish
is painted. Painted finish to be electrostatic baked
enamel and shall meet AAMA 603.8. Film thickness is
to be I mil. ± 0.2 mils. For non-standard finish,
contact manufacturer.
1.3.8 HARDWARE. Locking
arrangement at meeting rail shall be a device that
provides positive locking. All latching arrangements
at the meeting rail shall be easily replaced and repaired
without disassembly of sash members. Any window over
37 inches in height shall come standard with two locking
devices at the meeting rail. All windows shall meet
AAMA Specification 1302 and ASTM Spec F 588 for force
entry requirements. Locking arrangement on the meeting
rails shall be of the cam action type, pulling sash
together.
1.3.9 EXTERIOR PANNING SYSTEM.
Exterior panning system, where used, shall be extruded
aluminum of 6063-T5 or 6060-T5 aluminum alloy and
temper in 0.070' thickness to completely cover existing
exterior window frame. Panning depth of one inch or
less from the exterior face of the window frame can
be 0.062" wall a. Aluminum sections shall be
one piece designed to lock around the entire window
frame and be a completely weather tight connection
but allow unrestricted expansion and contraction of
panning members and window frame. The panning section
shall be secured at the comers with screws in integral
ports and back-sealed. The jamb, head, and sill are
to be sealed with a good grade of sealant meeting
AAMA Specification 808.3.
1.3.10 INTERIOR TRIM.
Interior trims, closures, angles, etc., If used, shall
be specified or detailed of extruded shapes with a
wall thickness of no less than .050" and of 6063-T5
aluminum alloy and temper. Snap trim dimensions will
be in accordance with dimensions as furnished in the
architecture details. On all interior trim, no exposed
fasteners shall be allowed.
1.4.1. Standard screen
members shall be of tubular extruded aluminum 6063-T5
or 6060-T5. Screens shall be provided when specified
and be of manufacturer's standard approved design.
Applicable to the specific window for which it is
intended with minimum frame dimensions of I 1/2"'
wide x 5/i6" deep.
1.4.2. Corners shall
be firmly joined in a secure and workmanlike manner,
utilizing staked in place cast corner keys. Frame
shall be of sufficient rigidity and cross-braced as
required to lie flat against window and prevent excess
bow in frame members and sag in screening.
1.4.3. Standard screen
cloth is aluminum 18 x 16 mesh securely held in frame
with vinyl spline and will meet the requirements of
CS138-55 "Insect Wire Screening' Fiberglass screen
wire is optional.
1.4.4. Screen shall
be spring loaded and held in place in an integral
screen track. Screen shall be easily removed and replaced
without the use of special tools.
Standard details (to scale) showing
all configurations, wall thickness and nature of materials
and methods for fastening and assembling shall be
submitted with the bid, if requested, The details
shall show generally existing conditions.
The window shall be installed square,
plumb, and level in a secure and professional manner
to assure neat and weather tight construction in accordance
with the ANSI/ASTM Specification F-737-80. A permanent
weather tight joint shall be made at the junction
of the sill and side frame members of the master frame
with a good grade of sealant that shall meet AAMA
Specification 803. Windows shall be properly caulked
with a compound meeting AAMA 808, 'Specifications
for Exterior Perimeter Sealing Compounds, " to
accomplish a thoroughly weather tight installation
around the perimeter of the window master frame.
| 1.7 PERFORMANCES
AND TESTING |
|
1.7.1 GENERAL. Except
as otherwise indicated, comply with air infiltration
tests, water resistance tests, uniform load deflection
tests, and uniform load structural tests specified
in ANSI/AAMA 101-97 for type and classification of
window units required in each case.
All units shall meet or exceed the requirements of
HC-65 and shall be designed for the loads specified
below.
a. Design load shall be 65 psf.
b. Test units shall be completely
assembled windows constructed in accordance with the
drawings unless otherwise specified. The units shall
be certified with the specified glazing and glazing
gaskets for this project unless the glazing of the
tested unit is of a heavier type.
1.7.2 AIR INFILTRATION
a. With the window sash and ventilators
closed and locked, test unit in accordance with ASTM
E-293 at a static air pressure difference of 1.57
psf.
b. Air infiltration shall not exceed
a maximum value of 0.10cfm/ft. for sash.
1.7.3 WATER RESISTANCE
a. With the window sash and ventilators
closed and locked, test unit in accordance with ASTM
E-331 at static air pressure difference of
9.75 psf.
b. There shall be no water leakage
as defined in ASTM E-331 at this specified static
air pressure difference to meet the performance requirement.
c. Test shall be completed with and
without exterior applied screens.
1.7.4 UNIFORM LOAD STRUCTURAL
a. With window sash and ventilators
closed and locked, test unit in accordance with ASTM
E-330 at a static air pressure difference of 97.5
psf with high pressure applied first on one side of
the unit and then on the other side.
b. Static air pressure difference
shall be 11/2 times the design load pressure of 65
psf.
C. At conclusion of test, there shall
be no glass breakage, permanent damage to fasteners,
hardware parts, support arms or actuating mechanisms
nor any other damage, which would cause the window
to be inoperable.
d. Permanent deformation of any window,
sash or ventilator member shall not exceed 4% of its
span.
1.7.5 CONDENSATION RESISTANCE
FACTOR (CRF)
a. With window sash and ventilators closed and locked.
Test unit in accordance with AAMA 1503.1-1988 using
test size of 4'0" by 6'0" and framing configurations
specified in the AAMA Specification Standards.
b. Condensation Resistance Factor
(CRF) shall not be less than 42.
1.7.6 THERMAL TRANSMISSION (CONDUCTIVE
U-VALUE)
a. With window sash and ventilators
closed and locked, test unit in accordance with AAMA
1503.1 using same test unit size and configuration
as used in 5 above.
b. Conductive thermal transmission
(U-Value) shall not be more than .56 BTU's/Hr./s.f./O°F
1.7.7 TESTING. Where
manufacturer's standard window units comply with requirements
and have been tested in accordance with specified
tests, provide certification by manufacturer showing
compliance with such tests; otherwise, perform required
tests through a recognized testing laboratory or agency
and provide certified test results.
a. DESIGN CRITERIA.
Drawings indicate sizes, profiles and dimensional
requirements of aluminum windows. Window units having
minor deviations from dimensions and profiles indicated
on drawings may be accepted, provided such deviations
do not materially detract from design concept or intended
performances and subject to approval of Contracting
Officer.
a. STANDARDS. Except
as otherwise indicated, requirements of aluminum windows,
terminology and standards of performance, and fabrication
workmanship are those specified and recommended in
ANSI/ AAMA 101-93.
a. PRODUCT DATA. Submit
manufacturer's technical product data, recommendations
and standard details for aluminum window units, including
certified test laboratory reports as necessary to
show compliance with all requirements of this specification.
b. SHOPDRAWINGS. Submit
shop drawings, including window schedules showing
locations, wall elevations at 1/2" scale, typical
unit elevations at 3/4" scale and full size detail
sections of every typical composite member. Show anchors,
hardware, operators, and other components not included
in manufacturer's standard data. Include glazing details.
c. SAMPLES. Submit samples
of each required aluminum finish, on 12" long
sections of extrusion shapes as required for window
units.
1. Contracting Officer reserves right
to require additional samples, which will show fabrication
techniques, workmanship of component parts, and design
of hardware and other exposed auxiliary items.
d. CERTIFICATION. Where
manufacturer's standard window units comply with requirements
and have been tested in accordance with specified
tests, provide certification by manufacturer showing
compliance with such tests; otherwise, perform required
tests through a recognized testing laboratory or agency
and provide certified results.
SPECIFICATIONS SUBJECT TO CHANGE